DC V | 6.000V/60.00V/600.0V/1000V Accuracy : ±(0.08%+2d) Input Impedance 10MΩ |
DC mV | 60.00mV/600.0mV Accuracy: ±(0.08%+5d) [60.00 mV] ±(0.08%+2d) [600.0 mV] Input Impedance: 10 MΩ |
AC V | 600.0mV/6.000V/60.00V/600.0V/1000V Accuracy: ±(1.2%+10d) 600.0mV at 45Hz~500Hz ±(0.8%+5d) 6.000V at 45Hz~1KHz, ±(0.8%+5d) 60.00/600.0/1000V (45Hz-1kHz) Input Impedance: 10 MΩ//less than 100pF |
DC V + AC V | 60.00mV/600.0mV/6.000V/60.00V/600.0V/1000V Accuracy:±(2%+5d) Input Impedance: 10 MΩ |
DC A | 60.00mA/600.0mA/6.000A/10.00A Accuracy: ±(0.8%+3d) |
AC A | 60.00mA/600.0mA/6.000A/10.00A Accuracy:±(1.2%+3d) at 45Hz~1KHz |
DC A + AC A | 60.00mA/600.0mA/6.000A/10.00A Accuracy:±(2%+5d) at 45Hz~1KHz |
Resistance | 600.0Ω/6.000KΩ/60.00KΩ/600.0KΩ/6.000MΩ/40.00MΩ Accuracy:±(0.8%+5d) 600.0Ω ±(0.8%+2d) 6.000KΩ/ 60.00KΩ/ 600.0KΩ/ 6.00MΩ ±(1.5%+5d) 40.00MΩ |
Auto-V LoZ | 600.0V/ 1000V Accuracy: ±(0.8%+3d) at 45Hz~1KHz Input Impedance: Approx. 3kΩ |
Continuity | Buzzer sounds <20Ω |
Frequency | 100.00Hz/1000.0Hz/10.000KHz/100.00KHz Accuracy: ±(0.1% + 2d) |
Diode Test | 1.5V/Open circuit voltage: Approx. 1.8V |
Capacitance | 1.000μF/10.00µF/100.0µF/1.000mF/10.00mF Accuracy:±(1.2%+5d) [1.000µF] ±(1.2%+2d) [10.00/100.0µF/1.000/10.00mF] |
Temperature | -40oC – 400oC Accuracy:±(1%+20d) |
Applicable Standards | Complies with EN 61010 CAT IV 600V, CAT III 1000V, EN 61326-1 |
Power Source | Single 9V battery (NEDA 1604A or IEC 6LF22) |
Dimension and Weight | 190mm(L) x 94mm (W) x 48 mm(H) with holster, 460g (including battery) |
Accessories | Model No. AC-91 (Test Leads), Model No. AC-80 (Alligator Clips), Model No. AR-16 (Temperature Probe), Protective holster, Magnetic Hanging Kit, ZnC battery (9V), Instruction Manual |