Model : 4402

1KV Insulation Tester with PI & DAR 4402
  • Insulation Test voltage of 50V, 100V, 250V, 500V & 1000V
  • Insulation Resistance measuring range upto 20GΩ
  • Automatic Calculation of Polarization Index and Dielectric Absorption Ratio
  • Large display with bar graph and backlight
  • Measures Voltage, Resistance, Continuity and LoΩ
  • Complies with EN61010 CAT IV 600V
  • img
  • img
  • img
  • img
  • img
  • img
  • img
  • img
  • img
  • img

Specifications

Test Voltage DC V
(Insulation Resistance)
   50V / 100V / 250V / 500V / 1000V
Measuring Range
(Insulation Resistance)
    1.0GΩ (50V)

2.0GΩ (100V)

5.0GΩ (250V)

10.0GΩ (500V)

20.0GΩ (1000V)

Accuracy
(Insulation Resistance)
   On 50V range

±(3%rdg+5dgt)

 

On 100V range

±(3%rdg+5dgt)

 

On 250V range

0.15MΩ – 1.50GΩ : ±(3%rdg+5dgt)

5GΩ : ±(10%rdg+3dgt)

 

On 500V range

0.30MΩ – 3.50GΩ : ±(3%rdg+5dgt)

10.0GΩ : ±(10%rdg+3dgt)

 

On 1000V range

0-60MΩ – 6.00GΩ : ±(3%rdg+5dgt)

20.0GΩ :  ±(10%rdg+3dgt)

Output current
(Insulation Resistance)
   1mA DC
Resistance measurement   0-600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ
Accuracy   2%rdg+5dgts
Continuity   0-600.0Ω ±(2%rdg+5dgt)
LoΩ   6.00Ω/60.00Ω
Voltage measurement   0-600V AC/DC
Accuracy

2%rdg+5dgts

Applicable Standards
(General)
   IEC61010-1 CAT IV 600V, EN 61326-1, IEC61557-1, IEC61557-2, IEC61557-4, IEC61557-10
Power Source
(General)
   LR6 1.5V (AA ) × 4
Dimension & Weight
(General)
   206(L) x 90(W) x 51(H)mm, Approx 630g (Including batteries)
Accessories
(General)
   Test Leads, Large Jaw Aligator clips,  Protective Holster, Carrying case,  Batteries LR6 x 4, Instruction manual